CHINESE JOURNAL OF ENERGETIC MATERIALS
+Advanced Search

Failure Modes of Electric Squib and Its Effect Factor
Author:
Affiliation:

Institute of chemical materials,CAEP

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
    Abstract:

    The failure modes of electric squib were studied during accelerated life test. The conditions of the aging test were temperature 71 ℃ and temperature 71 ℃, relative humidity 50% and 80%. The results show that the resistanc, fire time and output gass pressure did not change obviously, but the breakdown voltage dropped after accelerated life test. Especially, in the condition of humidity, the breakdown voltage of electric squib dropped significantly. By studying the effect factor to electric squib′s breakdown voltage, the reason was the inhomogeneous mixing of epoxy resin at the condition of humidity.

    Reference
    Related
    Cited by
Article Metrics
  • PDF:
  • HTML:
  • Abstract:
  • Cited by:
Get Citation

涂小珍,韦兴文,王培,等.电爆管失效模式及影响因素研究[J].含能材料,2012,20(1):117-119.
TU Xiao-zhen, WEI Xing-wen, WANG Pei, et al. Failure Modes of Electric Squib and Its Effect Factor[J]. Chinese Journal of Energetic Materials,2012,20(1):117-119.

Cope
History
  • Received:March 17,2011
  • Revised:April 25,2011
  • Adopted:May 18,2011
  • Online: February 23,2012