Based on the fast change of pressure in closed bomb tests, a heat flux equation focused on pressure factor was deducted. A one-dimensional semi-infinite model of calculating inwall heat transfer in closed bomb tests was established and the expression of heat transfer was obtained. The model was validated by double base aromatic-3 (SF-3), TEGDN (TG) propellant and triple-base propellant. The results show that the error between corrected whole heat loss and theoretical whole heat loss is less than 10%,and the burning rate pressure index of SF-3 propellant obtained is close to the expected value.
Reference
Related
Cited by
0
Article Metrics
PDF:
HTML:
Abstract:
Cited by:
Get Citation
赵军,廖昕,王泽山.密闭爆发器实验过程中的热散失修正研究[J].含能材料,2009,17(6):726-730. ZHAO Jun, LIAO Xin, WANG Ze-shan. Heat Loss Correction in Closed Bomb Tests[J]. Chinese Journal of Energetic Materials,2009,17(6):726-730.