CHINESE JOURNAL OF ENERGETIC MATERIALS
+Advanced Search

Effect of Charge Parameters on the Performance of Exploding Foil Initiator
Author:
Affiliation:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
    Abstract:

    To study the effect of HNS-Ⅳ charge parameters on the performance of exploding foil initiator (EFI),the function time of EFI with different charge parameters was measured. Results show that EFI with charge density of 90% theoretical maximum density (TMD) has the shortest function time and maximum initiation sensitivity. The initiation sensitivity of EFI with charge densities of 60% and 98%TMD is very low. When the charge density is 90%TMD,charge diameter has little effect on the initiation sensitivity and function time of EFI.

    Reference
    Related
    Cited by
Article Metrics
  • PDF:
  • HTML:
  • Abstract:
  • Cited by:
Get Citation

同红海,褚恩义,任西,等.装药参数对爆炸箔起爆器性能的影响[J].含能材料,2009,17(2):218-221.
TONG Hong-hai, CHU En-yi, REN Xi, et al. Effect of Charge Parameters on the Performance of Exploding Foil Initiator[J]. Chinese Journal of Energetic Materials,2009,17(2):218-221.

Cope
History
  • Received:September 11,2008
  • Revised:January 07,2009
  • Adopted:
  • Online: July 01,2009
  • Published: April 25,2009