Unilateral Tension Fracture Behavior of PEG/N-100 Matrix
Author:
Affiliation:
Fund Project:
Article
|
Figures
|
Metrics
|
Reference
|
Related
|
Cited by
|
Materials
Abstract:
The stress-strain relations and fracture behavior of the PEG/N-100 matrix were investigated by methods of unilateral tensile testing, scanning electron microscopy, etc.. The experimental results indicate that maximum tensile strength of the PEG/N-100 matrix is above 7 MPa and approximately 10 MPa at the yield point, and the elongation percentage of fracture is over 400%. The spherulites of about 7 μm in diameter were found in the fractured matrix of PEG/N-100. The process of the matrix fracture has been proved to undergo the growth of micro-cracks, the expansion of micro-cracks and the final fracture of PEG/N-100 matrix.
Reference
Related
Cited by
0
Article Metrics
PDF:
HTML:
Abstract:
Cited by:
Get Citation
唐根,郭翔,庞爱民,等. PEG/N-100弹性体单向拉伸断裂行为[J].含能材料,2007,15(4):356-358. TANG Gen, GUO Xiang, PANG Ai-min, et al. Unilateral Tension Fracture Behavior of PEG/N-100 Matrix[J]. Chinese Journal of Energetic Materials,2007,15(4):356-358.