CHINESE JOURNAL OF ENERGETIC MATERIALS
+Advanced Search

Treatment of TNT Wastewater by Supercritical Water Oxidation
Author:
Affiliation:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
    Abstract:

    The treatment of TNT wastewater were carried out by supercritical water oxidation (SCWO). The results show that SCWO can efficiently degrade organics in TNT wastewater with O2 oxidant. Reaction temperature,pressure, residence time and oxygen excess are the main influence factors in removing COD (chemical oxygen demand)of TNT wastewater. The COD removal efficiency can be notably improved as reaction temperature increases. With the temperature 550 ℃,the pressure 24 MPa, the residence time 120 s, and oxygen excess 300%, the COD removal rate is over 99.80%.

    Reference
    Related
    Cited by
Article Metrics
  • PDF:
  • HTML:
  • Abstract:
  • Cited by:
Get Citation

常双君,刘玉存.超临界水氧化处理TNT炸药废水的研究[J].含能材料,2007,15(3):285-288.
CHANG Shuang-jun, LIU Yu-cun. Treatment of TNT Wastewater by Supercritical Water Oxidation[J]. Chinese Journal of Energetic Materials,2007,15(3):285-288.

Cope
History
  • Received:August 22,2006
  • Revised:
  • Adopted:
  • Online: November 01,2011
  • Published: