CHINESE JOURNAL OF ENERGETIC MATERIALS
+高级检索
纳米TATB中微量残阴离子含量的离子色谱分析
作者:
作者单位:

(1. 中国工程物理研究院化工材料研究所, 四川 绵阳 621999; 2. 中国工程物理研究院含能材料测试评价中心, 四川 绵阳 621999)

作者简介:

陈玲(1986-),女,助理研究员,主要从事仪器分析工作。e-mail: chenling03@caep.cn 通信联系人: 黄伯勇(1971-),男,副研究员,主要从事材料理化性能表征。e-mail: 250667211@qq.com

通讯作者:

黄伯勇(1971-),男,副研究员,主要从事材料理化性能表征。e-mail: 250667211@qq.com

基金项目:

国家自然科学基金资助(11502250)


Ionic Chromatogram Method for Quantitative Analysis of Trace Component in Nano-TATB
Author:
Affiliation:

(1. Institute of Chemical Materials, CAEP, Mianyang 621999, China; 2. Energetic Materials Measurement and Evaluation Center of CAEP, Mianyang 621999, China)

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
    摘要:

    为评估纳米TATB产品质量, 采用氧瓶燃烧法处理样品, 用离子色谱测定吸收液中氯离子、硫酸根的方法来确定TATB中的微量组分含量。在Metrosep A Supp 7型阴离子分离柱上, 以4.7 mmol·L -1Na2CO3溶液作为淋洗液, 电导检测器进行检测。在优化的色谱条件下, 样品中氯离子、硫酸根的方法检出限分别为0.0025 ug·mL-1, 0.0032 ug·mL-1, 线性范围分别为(0.5~3.0) ug·mL-1, (0.1~2.5) ug·mL-1, 线性相关系数均大于0.9990。重复性测试(n=6) 相对标准偏差分别为1.65%、2.28%, 回收率分别为96.30%~103.73%, 97.23%~100.91%。该方法具有操作简单快捷、无污染等优点, 能满足纳米TATB中硫、氯的定量分析要求。

    Abstract:

    In order to assess the quality of nano-TATB, a simple and rapid method for the determination of Cl- and SO42- in the absorbent liquid by oxygen flask combustion-ionic chromatogram was developed to monitor the trace component of TATB. Na2CO3 solution with a concentration of 4.7 mmol·mL-1 was used as an eluate on an anion separation column of the model Metrosep A Supp 7 and conductivity detection. The method detection limits (MDL) of Cl- and SO42- were 0.0025 μg·mL-1 and 0.0032 μg·mL-1 respectively, under the optimized condition. The linear ranges of Cl- and SO42- were (500~3000) μg·L-1 and (100~2500) μg·L-1 respectively, and the correlation coefficients were all greater than 0.9990. The recoveries of the two analytes were 96.30%-103.73% and 97.23%-100.91% with the relative standard deviations (RSD, n=6) of 1.65%, 2.28%. The method has the advantage of simple operation, reagent-free and pollution-free, and can meet the quantitative analysis requirements of sulfur and chlorinous in nano-TATB.

    参考文献
    相似文献
    引证文献
文章指标
  • PDF下载次数:
  • HTML阅读次数:
  • 摘要点击次数:
  • 引用次数:
引用本文

陈玲,李哲,赵颖彬,等.纳米TATB中微量残阴离子含量的离子色谱分析[J].含能材料, 2017, 25(2):150-154. DOI:10.11943/j. issn.1006-9941.2017.02.010.
CHEN Ling, LI Zhe, ZHAO Ying-bin, et al. Ionic Chromatogram Method for Quantitative Analysis of Trace Component in Nano-TATB[J]. Chinese Journal of Energetic Materials, 2017, 25(2):150-154. DOI:10.11943/j. issn.1006-9941.2017.02.010.

复制
历史
  • 收稿日期: 2016-08-18
  • 最后修改日期: 2016-11-10
  • 录用日期: 2016-11-15
  • 在线发布日期: 2017-02-27
  • 出版日期: 2017-02-27