    摘要:

    为了满足深层石油勘探对震源高安全、低成本、耐高温、抗高压等技术要求,采用双气体管高压开关控制薄膜电容放电,通过S型桥箔电爆炸等离子体点火,实现了硼-硝酸钾(BPN)点火药的爆燃以及水下冲击波的输出,结合升降法确定了震源的最低发火条件,并利用压力传感器对震源的声学特性进行了研究。结果表明:由薄膜电容(2 μF)和双气体管高压开关组成的发火单元能够可靠实现脉冲放电,能够满足井下高温、高压的特殊环境,且成本较低;利用该发火单元对S型Cu桥箔放电,电爆炸等离子体引燃BPN药柱的电压阈值为1100 V,临界峰值电流为1847 A;水下冲击波实验及声源级分析结果表明该震源在50~800 Hz频带内激发的声源级高于150 dB,满足当前井下震源的技术要求。

    Abstract:

    In order to meet the multiple requirements of high safety, low cost, high temperature resistance, and high pressure resistance on the seismic source for deep oil exploration, a kind of high-voltage switch consisting of two gas discharge tubes (GDTs) was used to control the discharge of thin film capacitor, and S-type bridge foil was exploded into high-temperature and high-pressure gas/plasma to ignite the boron potassium nitrate (BPN) pellet and generate underwater shock waves. Then, the ignition threshold of the seismic source was determined by the up-down method, and the acoustic characteristics were also studied using pressure probe. The results show that the firing unit composed of a thin film capacitor (2 μF) and the high-voltage switch based on GDTs can reliably achieve pulse discharge, and work at the extreme underground environments such as high temperature and high pressure, and the cost is less than ¥10. Using the firing unit to stimulate the S-type Cu bridge foil, a firing voltage threshold of 1100 V and a critical peak current of 1847 A were determined. The measurements of underwater shock waves and acoustic source level (ASL) analysis show that the ASL excited by the seismic source is higher than 150 dB in the 50-800 Hz frequency band, meeting the requirements of underground seismic sources.